PULS
ML30.241
AC/DC Power supply unit (PSU) / converter with NEC Class 2 - PULS (MiniLine) - 24Vdc-28Vdc (adjustable) / 1.3A / 30W output - with screw-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-375Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)) - DIN rail mounting (23mm width) - equivalent to #ML30241
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Brand
SKU
ML30.241
Online Price
$115.00
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
ML30.241
Description
AC/DC Power supply unit (PSU) / converter with NEC Class 2 - PULS (MiniLine) - 24Vdc-28Vdc (adjustable) / 1.3A / 30W output - with screw-clamp connections - Single-phase (1AC) or DC input (85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz) / 88Vdc-375Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)) - DIN rail mounting (23mm width) - equivalent to #ML30241
Additional Information
#stock
Specifications
Primary brand
PULS
Main function
Power supply unit
Product series / family name
MiniLine series
Functions
AC/DC Power supply unit (PSU) / converter
Design
NEC Class 2
Supply voltage (AC)
85Vac-264Vac (100Vac / 110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac / 240Vac nom.; 47-63Hz)
46Vac turn-ON voltage
44Vac shutdown voltage
46Vac turn-ON voltage
44Vac shutdown voltage
Supply voltage (DC)
88Vdc-375Vdc (100Vdc / 110Vdc / 120Vdc / 127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)
Type of network
Single-phase (1AC) or DC
Rated current
1.3A (at 24Vdc)
Rated power
30W
Output voltage (DC)
24Vdc-28Vdc (adjustable)
250mV turn-ON overshoot
250mV turn-ON overshoot
Connection type
screw-clamp connections
Protection functions
NTC (input inrush current limiter)
Efficiency
0.885 (230Vac input)
0.894 (120Vac input)
0.894 (120Vac input)
Net Width (mm)
23 mm
Mounting mode
DIN rail mounting
Dimensions
W23mm x H75mm x D91mm
Material
PC / ABS blend housing
Ambient air temperature for operation
-10...+70 °C
Current consumption
18A max. inrush (at 120Vac input)
35A peak max. inrush (at 230Vac input)
35A peak max. inrush (at 230Vac input)
Power dissipation/losses
3.7 W
Power factor (cos phi)
0.49
Manufacturer product status
Commercialized
Equivalent to
ML30241
Capacitance
(output stage) 900 μF
Compliant with standard(s)
SN 29500
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
NEC CLASS 2
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
CE marking
UL 508
UL 60950-1
IEC 60950-1 CB-Scheme
Class I Div. 2 HazLoc
GL Marine
ABS Marine
EAC Registration
NEC CLASS 2
EN 61000-6-1 Immunity for residential environments
EN 61000-6-2 Immunity for industrial environments
EN 61000-6-3 Emission for residential environments
EN 61000-6-4 Emission for industrial environments
EN 55011 / EN 55022 class B Disturbance characteristics
Benefits
A compact size; light weight; simple mounting onto the DIN-rail and the utilization of only quality components are what makes the MiniLine power supplies so easy to use and install within seconds.
A rugged electrical and mechanical design as well as a high immunity against electrical disturbances on the mains provides reliable output power.
This offers superior protection for equipment which is connected to the public mains network or is exposed to a critical industrial environment.
A rugged electrical and mechanical design as well as a high immunity against electrical disturbances on the mains provides reliable output power.
This offers superior protection for equipment which is connected to the public mains network or is exposed to a critical industrial environment.
Electrical durability
174kh (min; at +40°C) / 174 000 hours
Ripple
50mVpp (20Hz...20MHz; 50Ω)
MTBF (Mean Time Between Failures)
2405kh (at +40°C) / 2 405 000h
Time delay
90ms start-up delay (100-230Vac input)
40ms rise time (nominal input; constant full current load; 0mF load capacitance)
90-100ms rise time (nominal input; constant full current load; 1.3mF load capacitance)
40ms rise time (nominal input; constant full current load; 0mF load capacitance)
90-100ms rise time (nominal input; constant full current load; 1.3mF load capacitance)
Related Documents
Name | Last Update | Language |
---|---|---|
PULS - Power supply units - Catalog.pdf | 01 Oct 2021 | English (US) |
PULS - ML30-241-2 - Datasheet.pdf | 01 Oct 2021 | English (US) |